Türkiye Prefabrik Birliği | Sayı: 136
        
 MAKALE BETON PREFABRİKASYON EKİM 2020 ◆ SAYI : 136 22 [8] Khoo, H.-H., Clifton, C., But- terworth, J., MacRae, G., Gled- hill, S., & Sidwell, G. (2012). De- velopment of the self-centering Sliding Hinge Joint with friction ring springs. Journal of Cons- tructional Steel Research, 78 pp. 201-211. [9] Wolski, M., Ricles, J. M., & Sa- use, R. (2009). Experimental Study of a Self-Centering Beam- Column Connection with Bottom Flange Friction Device. Journal of Structural Engineering, 135(5) pp. 479-488. [10] Ghayeb, H. H., Razak, H. A., & Sulong, N. H. R. (2017). Deve- lopment and testing of hybrid precast concrete beam-to-co- lumn connections under cyclic loading. Construction and Buil- ding Materials, 151 pp. 258-278. [11] Choi, H.-K., Choi, Y.-C., & Choi, C.-S. (2013). Development and testing of precast concrete be- am-to-column connections. Engineering Structures, 56 pp. 1820-1835. [12] Wu, C., Yu, S., Liu, J., Chen, G. (2020) “Development and testing of hybrid precast steel-reinforced concrete columnto-H shape steel beam connections under cyclic loading” Engineering Structures 211 pp. 1-17. [13] Zhang, J., Ding, C., Ronga, X., Yang, H., Wang, K., Zhang B. (2020) “Experimental seismic study of precast hybrid SFC/ RC beam-column connections with different connection details” Engineering Structures 208 pp. 1-18. [14] Zhong, Y., Xiong, F., Chen, J., Deng, A., Chen, W., Zhu, X., (2019) “Experimental Study on a Novel Dry Connection for a Precast Concrete Beam-To-Co- lumn Joint” Sustainability. 11 pp. 1-22. [15] Esmaeili, J., Ahooghalandary, N., “Introducing an easy-install pre- cast concrete beam-to-column connection strengthened by steel box and peripheral plates” Engi- neering Structures 205 pp. 1-20. [16] Yuksel, E., Karadogan, H.F., Bal, I.E., Ilki, A., Bal, A., Inci, P. (2015) “Seismic behavior of two exterior beam-column connec- tions made of normal-strength concrete developed for precast construction” Engineering Struc- tures 99 pp. 157-172. [17] Li, Y., Ding, Y., Geng, F., & Wang, L. (2019). Seismic response of self-centering precast concrete frames with hysteretic dampers. The Structural Design of Tall and Special Buildings, 1604. [18] Lu, C., Dong, B., Pan, J., Shan, Q., Hanif, A., & Yin, W. (2018). “An investigation on the behavior of a new connection for precast structures under reverse cyclic loading” Engineering Structures 169 pp. 131-140. [19] Lu, Z., Huang, J., Dai, S., Liu, J., & Zhang, M. (2019).”Experimen- tal study on a precast beam-co- lumn joint with double grouted splice sleeves” Engineering Stru- ctures 199 pp. 1-17. [20] Gou, S., Ding, R., Fan, J., Nie, X., & Zhang, J. (2019). “Experimen- tal study on seismic performance of precast LSECC/RC composite joints with U-shaped LSECC beam shells” Engineering Struc- tures 189 pp. 618-634. [21] Hu, G., Huang, W., & Xie, H. (2020). “Mechanical behavior of a replaceable energy dissipa- tion device for precast concre- te beam-column connections” Journal of Constructional Steel Research 164 pp. 1-19. [22]  https://www.som.com/ [23] ANSI/AISC 358-16 Prequalified Connections for Special and In- termediate Steel Moment Frames for Seismic Applications, inclu- ding Supplement No. 1. [24] Aninthaneni, P.K., Dhakal, R.P., Marshall, J., & Botara, J. (2020). “Experimental investigation of “dry” jointed precast concrete frame sub-assemblies with ste- el angle and tube connections”. Bulletin of Earthquake Enginee- ring, 18, pp. 3659-3681.
        
         powered by ikedijital.com 
RkJQdWJsaXNoZXIy MTczMDA=